INDUSTRY (FACILITY) |
SERVICE | PARAMETER | RANGE | BACKGROUND | TELEDYNE MODEL |
---|---|---|---|---|---|
Continuous Catalytic Reformer - CCR: See application note in Petrochemical for Aromatic Plant | |||||
Fluid Catalytic Cracker Unit - FCCU - 1st & 2nd Stage Regenerator Cyclones | |||||
Catalyst regeneration | Percent O2 Percent CO Percent O2 |
0-1% 0-1%, 0-10% 0-1, 0-5, 0-25% |
Flue gas | Series 9000 extractive 7500Z NDIR 320P plus sample system |
|
Flue gas / stack incinerator | Percent O2 & SO2 | 0-5% O2 & 0-1% | Flue gas | 6000 UV (SO2) /3000P (O2) | |
Desulfide separator vent gas | Percent O2 | 0-25% | Process gas | 3020MParamagnetic | |
Hydrocracker Unit | |||||
Recycled gas compressor suction Make-up gas Total gas downstream confluence point |
Percent H2 | 50-100% | Hydrocarbons | 2020 | |
Crude & Vacuum Distillation Units - CDU & VDU | |||||
Color analysis / Diesel product | ASTM / APHA / Saybolt | Product dependent | Fuel oil | 6000 UV | |
2 Naphtha pumparound to Atm crude tower | Product dependent | Light naphtha | 6000 UV | ||
CDU / VDU Heaters | |||||
Stack gas / CEM Appl | PPM NOx / SOx | 0-500 ppm | Stack gas | 9110TH & 6000 UV | |
Cooling Tower Water | |||||
Hydrocarbon breakthrough | PPM hydrocarbons | 0-10 ppm | Water | 4020 & 1100A stripper | |
INDUSTRY (FACILITY) |
SERVICE | PARAMETER | RANGE | BACKGROUND | TELEDYNE MODEL |
PSA Unit | |||||
H2 purification off gas | PPM CO | 0-10 ppm | H2 | 7500Z NDIR Series | |
Sulfur Recovery Unit (SRU) | |||||
Flue gas to SRU stack incinerator | Percent O2 & SO2 | 0-5%O2 0-1% SO2 |
Flue gas | 3000P (O2) / 6000(SO2) | |
Tail Gas Treating Unit (TGTU) | |||||
SCOT quencher overhead Recycle gas compressor discharge |
Percent H2 | 0-4, 0-8% 70-100% |
N2 / CO2 / H2S CH4, H2S + trace HC |
2020 | |
Recycle gas to gas scrubber Recycle gas scrubber overhead |
Percent H2S PPM H2S |
0-5% 0-2000 ppm |
H2, CH4, H2O H2, CH4, H2O |
6000 (UV) | |
Carbon Black Unit | |||||
Partial combustion - furnace process | % O2 | 0-5% | C.B + H.C + CO | 9500 (dirty application) | |
Methanol / MTBE | Purge gas to reformer Methanol convertor effluent |
% H2 | 70-100% | CH4 / CO2 / CH3OH CH4 / CO2 / CO / N2 |
2020 |
CD Tech, UOP, ABB Lummas | Circulator gas compressor Net gas from knockout pot |
% H2 | 70-100% 50-100% |
CH4 / CO2 / CO / N2 C1, C2, C3, C4 |
2020 |
Reactor column - purification | % CH3OH | 0-2% | MTBE | 5020 (NIR) | |
MTBE in gasoline | % MTBE | 0-20% | Gasoline | 7300 (NDIR) |