INDUSTRY (FACILITY) |
SERVICE | PARAMETER | RANGE | BACKGROUND | TELEDYNE MODEL |
---|---|---|---|---|---|
Lime kiln | Detection of CO to control feed of excess air | PPB CO | 0-1000 ppm | N2, O2, CO2, H2Ov | |
Used for combustion and after cooling. Too much air drives particulates through gas recovery section and overloads baghouse. | |||||
Black liquor recovery (BLR) | Combustion efficiency analysis BL = waste laden fuel |
% O2, PPM CO and / or Percent combustibles |
0-5% O2, 0-1% CO | Extremely dirty application | Series 9000 extractive |
CLO2 Detection | Absorber / storage / bleaching | PPM CLO2 | 0-1000 ppm COCL2 | Air or water | Series 6000UV |
NaOCL detection | Caustic scrubber | PPM NaOCL | 0-1500 ppm | Water | Series 6000UV |