INDUSTRY (FACILITY) |
SERVICES | PARAMETER | RANGE | BACKGROUND | TELEDYNE MODEL |
---|---|---|---|---|---|
Flue Gas Desulferization (FGD) | Inlet to fluidized bed / absorber Outlet from fluidized bed / absorber |
Percent SO2 PPM SO2 |
00-1% 0-250, 0-500 ppm |
Flue gas | Series 6000 UV |
ON-LINE / CONTINUOUS | |||||
Excess O2 Combustion efficiency |
Stack gas analysis | Percent O2 PPM CO Percent combustibles |
0-5% 0-1000 ppm 0-5% CH4 eq |
Flue gas | 9060Z (ZrO2) 7500Z 9700 for heavy, solid fuels |
Pollution abatement | Continuous emission monitor CEM / Stack gas |
PPM SO2 PPM NOx |
0-250 to 0-5000 ppm 0-10 to 0-5000 ppm |
Flue gas | 6000 (UV) / IR-7000 (NDIR) 9110TH Chemiluminescence |
Boiler tube control | Oil in boiler return steam condensate | PPM oil | 0-10 ppm | Condensate | 6600 (UV) |
Cooling water | Hydrocarbons in cooling H2O | PPM hydrocarbons | 0-10 ppm | Water | 4020 + 1100A stripper |
INDUSTRY (FACILITY) |
SERVICES | PARAMETER | RANGE | BACKGROUND | TELEDYNE MODEL |
PORTABLE ANALYZERS | |||||
Excess O2 / Boiler | Stack gas analysis | Percent O2 Percent O2; PPM CO Comb |
0-5% | Flue gas | 320P, 320PD Max 5 / PEM-9004 |
Pollution abatement | Stack gas analysis | Percent O2; PPM CO, SO2, NO, NO2; Percent CO2 |
See data sheet | Flue gas | PEM-9004 |
H2 Turbine Generator | H2 purity / turbine maintenance | Percent H2, CO2, Air | See data sheet | Air, H2, CO2 | 275R |
SF6 Filling | Electrical apparatus / switchbox | PPM O2 | 0-10 ppm | SFG | 311 |
Bechtel Spec | Battery room analysis | % H2 | 0-100% LEL | Air | 1223 commercial grade |
BNFL (UK) | Nuclear fuels conversion of uranium ores to UF6 Effluent control of fluorine |
% F2 | 0-50% | UF6, HF, O2, CF4 | Series 6000 UV (commercial) |
KEPCO - Korea | Gaseous waste treatement | % O2 | 0-5, 0-10% | N2 | Series 3000(commercial) |
KEPCO - Korea | Deuterium (D2) in air | % D2 | 0-5% | Air | Series 2000(commercial) |
INDUSTRY (FACILITY) |
SERVICES | PARAMETER | RANGE | BACKGROUND | TELEDYNE MODEL |
Vacuum Drag System | Recombiner (after condensor) Feed to off gas compressors aka Catalytic recombiner of radwaste gas mixture |
% H2 % O2 |
0-5% H2 0-5% O2 |
O2 / N2 N2 / H2 |
Series 2000(commercial) Series 3000(commercial) |
Desalination plant | Seawater electrochlorination unit efficiency performance | PPM NaOCL (hypochlorite ion) | 0-1500 ppm | Seawater | Series 6000 (UV) |